GB 50016-2018 PDF English


Search result: GB 50016-2018_English: PDF (GB50016-2018)
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 50016-2018195 Add to Cart Auto, < 3 mins [2018 Edition of GB 50016-2014] Code for Fire Protection Design of Buildings [Code of Design on Building Fire Protection and Prevention]
GB 50016-2014195 Add to Cart Auto, < 3 mins [2018 Edition] Code for Fire Protection Design of Buildings [Code of Design on Building Fire Protection and Prevention] Obsolete
GB 50016-2006230 Add to Cart Auto, < 3 mins Code of Design on Building Fire Protection and Prevention Obsolete

GB50016-2018: PDF in English

GB 50016-2014 (2018 Edition) UDC NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA P GB 50016-2014 Code for Fire Protection Design of Buildings (2018 Edition) ISSUED ON: AUGUST 27, 2014 IMPLEMENTED ON: MAY 1, 2015 Issued by: Ministry of Housing and Urban-Rural Development of the People's Republic of China; General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China. Table of Contents Foreword ... 7 1    General Provisions ... 14 2    Terminologies and Symbols ... 16 2.1 Terminologies ... 16 2.2 Symbols ... 19 3    Factory‐buildings and Storages ... 20 3.1 Classification of Fire Hazards ... 20 3.2 Fire Resistance Class of Factory-buildings and Storages ... 22 3.3 Storeys, Occupied Area and Plane Arrangement of Factory-buildings and Storages ... 26 3.4 Fire Separation Distance of Factory-buildings ... 34 3.5 Fire Separation Distance of Storages ... 41 3.6 Explosion Prevention of Factory-buildings and Storages ... 44 3.7 Safe Evacuation of Factory-buildings ... 47 3.8 Safe Evacuation of Storages ... 49 4    Class A, B, C Liquid and Gas Tanks (Tank Farm) and Stackyard for Combustibles . 51 4.1 General Requirements ... 51 4.2 Fire Separation Distance of Class A, B, C Liquid Tanks (Tank Farm) ... 51 4.3 Fire Separation Distance of Combustible and Combustion-supporting Gas Tanks (Tank Farm) ... 56 4.4 Fire Separation Distance of LPG Tanks (Tank Farm) ... 63 4.5 Fire Separation Distance of Stackyard for Combustibles ... 65 5    Civil Buildings ... 69 5.1 Classification and Fire Resistance Class ... 69 5.2 General Layout ... 72 5.3 Fire Compartment and Storeys ... 75 5.4 Plane Arrangement ... 79 5.5 Safe Evacuation and Refuge ... 88 6    Building Construction ... 104 6.1 Fire Wall ... 104 6.2 Building Elements and Pipe Shafts ... 105 6.3 Roof, Blind Ceiling and Joints ... 108 6.4 Evacuation Staircases and Stairs ... 109 6.5 Fire Door, Window and Fire Roller Shutter ... 115 6.6 Overpass, Trestle and Pipe Trench ... 117 6.7 Building Insulation and Exterior Wall Finish System ... 117 7    Fire Fighting and Rescue Facilities ... 121 7.1 Fire Lane ... 121 7.2 Field for Fire Fighting ... 123 7.3 Fire Elevator ... 124 7.4 Helicopter Landing Pad ... 126 8    Arrangement of Fire‐fighting Facilities ... 127 8.1 General Requirements ... 127 8.2 Indoor Fire Hydrant System ... 129 8.3 Automatic Fire Extinguishing System ... 130 8.4 Fire Alarm System ... 136 8.5 Smoke Control and Smoke Exhaust System ... 138 9    Heating, Ventilating and Air Conditioning ... 140 9.1 General Requirements ... 140 9.2 Heating ... 140 9.3 Ventilating and Air Conditioning ... 141 10    Electric System ... 146 10.1 Fire Power Supply and Distribution ... 146 10.2 Power Line and Electric Equipment ... 148 10.3 Fire Emergency Lighting and Evacuation Indicating Sign ... 150 11    Timber Buildings ... 153 12    City Road Tunnel ... 159 12.1 General Requirements ... 159 12.2 Fire Water Supply and Fire Extinguishing Equipment ... 161 12.3 Ventilating and Smoke Exhaust System ... 163 12.4 Fire Alarm System ... 164 12.5 Power Supply and Other Requirements ... 165 Appendix A ‐‐ Calculation Method of Building Height and Storeys ... 166 Appendix B ‐‐ Calculation Method of Fire Separation Distance ... 168 Appendix  C  ‐‐  Temperature‐rise  Curve  for  Fire  Resistance  Rating  Test  and  Performance Criteria of Load‐bearing Structure in Tunnel ... 169 Explanation of Wording in This Code ... 170 List of Quoted Standards ... 171 1 General Provisions 1.0.1 This code is formulated with a view to preventing fire accidents in buildings, reducing fire hazards and protecting personal and property safety. 1.0.2 This code is applicable to the following constructed, renovated and extended buildings: 1 Factory-buildings; 2 Storages; 3 Civil buildings; 4 Class A, B, C liquid tanks (tank farm); 5 Combustible and combustion-supporting gas tanks (tank farm); 6 Stackyard for combustibles; 7 City road tunnels. If special national standards are available, the fire protection design of buildings for civil air defense engineering, petroleum and natural gas engineering, petrochemical engineering, thermal power plants and substations should comply with such standards. 1.0.3 This code is not applicable to the fire protection design of buildings such as factory-buildings (storages) for gunpowder, explosive and their products as well as fireworks and firecrackers. 1.0.4 Where occupancies for different purposes are arranged in the same building, fire separation shall be provided between them. The fire protection design for this building and their functional occupancies shall be determined according to the relevant requirements of this code. 1.0.5 The fire protection design of buildings shall comply with the relevant national principles and policies, and guarantee, on the whole, safety and usability, advanced technology as well as economy and rationality according to the characteristics of buildings and fire hazards in them. 1.0.6 In addition to meeting the requirements of this code, the buildings with height single-storey Category D factory-buildings with building area not greater than 1,000m2, the fire resistance class may adopt Class III. 3.2.4 As for the buildings using or storing particularly valuable equipment or articles such as machinery, instruments and apparatuses, the fire resistance class shall not be less than Class II. 3.2.5 The fire resistance class of boiler house shall not be less than Class II. In case of coal-fired boiler house with total evaporation not larger than 4t/h, its fire resistance class may adopt Class III. 3.2.6 The fire resistance class of oil immersed transformer room and high-voltage distribution device room shall not be less than Class II, and other fire protection design shall meet the requirements of current national standard "Code for Design of Fire Protection for Fossil Fuel Power Plants and Substations" (GB 50229) and other relevant standards. 3.2.7 The fire resistance class of high rack storages, high-rise storages, Category A storages, multi-storey Category B storages and multi-storey Category C storages storing combustible liquid shall not be less than Class II. The fire resistance class of single-storey Category B storages, single-storey Category C storages, multi-storey Category C storages storing combustible solids and multi-storey Categories D and E storages shall not be less than Class III. 3.2.8 The fire resistance class of grain silos shall not be less than Class II; the grain silo with Class II fire resistance may adopt steel silo. The fire resistance class of grain storehouses shall not be less than Class III; the bulk grain storehouses with Class II fire resistance may be adopted with metal load-bearing elements without fire protection. 3.2.9 The fire resistance rating of fire walls in Categories A and B factory-buildings and Categories A, B and C storages shall not be less than 4.00h. 3.2.10 The fire resistance rating of columns in single-storey factory-buildings (storages) with Class I or II fire resistance shall not be less than 2.50h and 2.00h respectively. 3.2.11 As for the Class I fire resistance single-/multi-storey factory-buildings (storages) with full protection of sprinkler system, the fire resistance rating of their roof load-bearing elements shall not be less than 1.00h. 3.2.12 Except Categories A and B storages and high-rise storages, if the non-load-bearing exterior walls of buildings with Class I or II fire resistance adopt non-combustible wall body, their fire resistance rating shall not be less than 0.25h; if they adopt difficult-combustible wall body, their fire resistance rating shall not be less than 0.50h. As for the 4-storey or less Categories D and E over-ground factory-buildings (storages) with Class I or II fire resistance, if their non-load-bearing exterior walls adopt non-combustible wall body, their fire resistance rating is not limited. 3.2.13 As for factory-buildings (storages) with Class II fire resistance, if the partition wall between rooms in them adopt difficult-combustible wall body, the fire resistance rating shall be increased by 0.25h. 3.2.14 As for the prestressed reinforced concrete floor slabs in multi-storey factory-buildings with Class II fire resistance, the fire resistance rating shall not be lower than 0.75h. 3.2.15 As for the accessible flat roof of factory-buildings (storages) with Class I or II fire resistance, the fire resistance rating of the roof slab shall not be less than 1.50h and 1.00h respectively. 3.2.16 The roof slab of factory-buildings (storages) with Class I or II fire resistance shall be made of non-combustible materials. The roof waterproof layer should adopt non-combustible or difficult-combustible materials. If combustible waterproof materials are adopted and laid over combustible or difficult-combustible thermal insulation materials, the waterproof materials or the combustible/difficult-combustible thermal insulation materials shall be protected with non-combustible materials. 3.2.17 If it is necessary to adopt metal sandwich panels as the non-load-bearing exterior wall, partition walls between rooms and roof slab in buildings, the core material shall be non-combustible and its fire resistance rating shall meet the relevant requirements of this code. 3.2.18 Unless otherwise stated in this code, the fire resistance class of such factory-buildings (storages) with load-bearing wooden columns and with walls made of non-combustible materials may be determined as Class IV. 3.2.19 Proper fire protection measures shall be taken at the exposed joint positions of precast reinforced concrete elements, and the fire resistance rating of joints shall not be less than that of corresponding elements. values stated in this table and it is indeed difficult to build fire.......
Source: https://www.ChineseStandard.net/PDF.aspx/GB50016-2018